Many users suddenly think of the diesel generator set when the power is cut off, but when they really use it, many hidden problems emerge, such as slow start-up, unstable power generation and so on. In the final analysis, users almost never maintain the 3 diesel generator set after they buy it. They just keep it there all the time, and some can even keep it for several years, In this case, it must be difficult to use diesel generator set. So we need to maintain the generator set regularly. What do we need to do?

First, water enters the generator set. It may be rain soaked, it may be the temperature difference of the air, which produces water vapor, condenses and flows into diesel or other parts. Over time, it will cause serious unit damage.

Second, the shelf life of diesel generator set oil. The engine oil of the unit plays the role of lubrication in the machinery, and the engine oil also has a certain shelf life. If it is stored for a long time, the physical and chemical properties of the engine oil will change, resulting in the deterioration of the lubrication condition of the unit during operation, which is easy to cause damage to the parts of the diesel generator set. Therefore, the lubricating oil should be replaced regularly to avoid the expiration of a long time.

Third, the starting battery failure of diesel generator set. If the battery is not maintained for a long time, the electrolyte water is not replenished in time after volatilization, and there is no charger configured to start the battery, the power of the battery will be reduced after natural discharge for a long time, or the charger used needs to be manually and regularly switched between equalizing and floating charge, which will lead to the battery power failure to meet the requirements due to negligence, Therefore, to solve this problem, in addition to configuring high-quality chargers, necessary detection and maintenance are very necessary.

Fourth, the replacement cycle of the three filters of the unit. Three filters are used to filter diesel, engine oil or water, and prevent impurities from entering the engine. Oil and impurities in diesel are also inevitable. Therefore, during the operation of generator set, the filter plays an important role, but at the same time, these oil or impurities are deposited on the filter screen wall, reducing the filtering capacity of the filter and causing excessive deposition, The oil circuit will not be unblocked, so the oil engine will be shocked due to the lack of oil supply during on-load operation, so the three filters need to be replaced periodically.